Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

10/03/19

Message Overview:

Fault Message:

R EEC CH A FAULT[7]

Fault Code:

7325424RBR

Associated CAS:

R FADEC FAIL
(Caution)

Reporting LRU: Right Engine Electronic Controller (EEC)
System Description: 76-10-00
Schematic Diagram: 76-10-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 71-50-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

There is an internal fault in the Engine Electronic Controller (EEC). This message can be related to a problem in the IOP harness between the EEC and the Fuel Metering Unit (FMU). If the CAIMS message R IOP CH A WRG/FMU[IOP SOL] shows, you must do that fault isolation procedure first.

NOTE: The incidence of L (R) IOP CH A WRG/FMU[IOP SOL] can cause damage to the EEC during the checks of IOP shutdown. If any faults are not corrected, damage to the replacement EEC can occur.

Possible Causes:

  • Right Engine Electronic Controller (EEC)
  • Fuel Metering Unit (FMU)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

Forum Articles/Infoservice/Newsletter:

Quick Links:

Removal of the Eng Electronic Controller (EEC) EMM 73-21-01-000-801-B00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Eng Electronic Controller (EEC) EMM 73-21-01-400-801-B00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Using the CAIMS, clear the EEC memory.
    NOTE: THIS FAULT MESSAGE IS STORED / LATCHED WITHIN THE EEC NVM. CYCLING OF THE EEC POWER OR SWAPPING OF THE EEC TO ANOTHER ENGINE WILL NOT CLEAR THE FAULT / EICAS MESSAGE.
  2. Perform an engine run and shut down to confirm if CAIMS message R IOP CH A WRG/FMU[IOP SOL] or R EEC CH A FAULT[7] shows.

    1. If the fault R EEC CH A FAULT[7] shows, continue with step 4.
    2. If both fault messages show or none, continue with next step.

  3. Make sure to troubleshoot the CAIMS Fault message R IOP CH A WRG/FMU [IOP SOL] first.

    1. If both fault indications are gone, do close out.
    2. If fault message remains, continue with next step.

  4. Replace Right EEC.
  5. Do close out.