Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/22/21

Message Overview:

Message Name:

DCPC TERMINAL GUARD BROKEN

Message Code: 240OBS004
Effectivity: All
System: Electrical Power
System Description: 24-00-00
Schematic Diagram: None
Wiring Diagram: None

Message Description:

DC Power Center (DCPC) Terminal Guards found damaged.

Possible Causes:

None

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter:

Quick Links:

Repair of the DC Power Center (DCPC)
Terminal Guard
AMM 24-61-00-340-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. The broken terminal guard can be repaired permanently as per AMM task.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. In the case of the broken piece is missing, a terminal guard strip P/N 769546 can be ordered and used to repair the broken terminal guard on the DCPC.
  3. Do close out.