Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/29/21

Message Overview:

Message Name:

PILOT FLOOR HEATERS UNSERVICEABLE

Message Code: 251OBS003
Effectivity: All
System: Flight Crew Seats
System Description: 25-11-00
Schematic Diagram: 25-13-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 25-13-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

The Floor Heater does not operate. The result is that the air temperature is colder at the Flight Crew Floor.

Possible Causes:

  • Secondary Power Distribution Assembly (SPDA) 1 (A13)
  • Pilot Floor Heater 1 (HR4)
  • Pilot Floor Heater 2 (HR5)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Notice To Operators (NTO): None

Flight Operation Notifications Manual (FONM): None

NOTE: No troubleshooting is necessary when no ELT/NAV interface unit is installed.

Quick Links:

Removal of the Flight Crew Floor-Heaters AMM 25-13-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Flight Crew Floor-Heaters AMM 25-13-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform wiring check between SPDA 1 and pilot floor heaters.

    From To Result
    HR4J1-A A13P2-H
    HR4J1-B GS306
    HR5J1-A A13P2-H
    HR5J1-B GS306

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  2. Replace defective pilot floor heater.
  3. Do close out.