06/30/21
Message Overview:
Message Name:
WING CROSS-BLEED VALVE MECHANICALLY OPEN WITH CLOSED POSITION INDICATION ON EICAS
| Message Code: | 301OBS010 |
| Effectivity: | All |
| System: | Anti-Ice System |
| System Description: | 30-11-00 |
| Schematic Diagram: | 30-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The Wing Cross-Bleed Valve is mechanically open while a closed position shows on the Engine Indication and Crew Alerting System (EICAS).
Possible Causes:
- Wing Cross Bleed Valve (L33)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Wing Cross-Bleed Valve | AMM 30-11-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Wing Cross-Bleed Valve | AMM 30-11-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the External Avionics-Compartment Access-Panel (140BB) |
AMM 52-45-11-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the External Avionics-Compartment Access-Panel (140BB) |
AMM 52-45-11-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Belly Fairing Access-Panels (181BB, 183BB, 185BL/186BR, 185CL/186CR) |
AMM 53-61-19-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Belly Fairing Access-Panels (181BB, 183BB, 185BL/186BR, 185CL/186CR) |
AMM 53-61-19-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the wing cross-bleed valve, check that the manual lever is at the OPEN position.
- If the manual lever is not at the OPEN position, set it to open position and continue with next step.
- If the manual lever is at the OPEN position, continue with next step.
- Disconnect the electrical connector (L33P1) from the cross-bleed valve (L33). Perform a continuity check between pins of the electrical receptacle of the cross-bleed valve as follows:
From To Result L33J1-5 L33J1-6 - If there is continuity, go to step 5.
- If there is no continuity, continue with next step.
- Perform a continuity check between pins of the electrical receptacle of the cross-bleed valve as follows:
From To Result L33J1-1 L33J1-6 - If there is no continuity, go to step 5.
- If there is continuity, continue with next step.
- Disconnect the electrical connector (JB3AP1) from the JB3 and perform the continuity check as follows:
From To Result JB3AP1-5E Ground JB3AP1-5D Ground JB3AP1-4E Ground JB3AP1-4B Ground - If there is continuity, repair or replace the defective wiring as required and go to step 6.
- If there is no continuity, go to step 6.
- Replace the wing cross-bleed valve.
- Re-connect all the disconnected electrical connectors.
- Do close out.