Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

03/13/26

Message Overview:

Message Name:

INTERNAL FAULT

Message Code:

B3-007088

Associated CAS:

L GEN FAIL
(Caution)

Reporting LRU: LEFT GENERATOR
System Description: 24-31-00 - Primary DC Power System
24-61-00 - DC Power Center (DCPC)
Schematic Diagram: SSM 24-31-00-101 - Primary DC-Power System
SSM 24-61-00-101 - DC Power Center (DCPC) System
Wiring Diagram: 24-31-05 - Main Generator (Left) - ALL
24-31-13 - Generator Control Unit (GCU) Left - ALL
24-61-01 - DC Power Center (DCPC) Left - ALL

Message Description:

The Left Generator (LGEN) has failed.

Possible Causes:

  • Left Generator (LGEN) (G1)
  • Left Generator Control Unit (LGCU) (PCB5)
  • Left Generator Power Module (LGPM) (PCB7)
  • Left DC Power Center (LDCPC) (A35)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW300-24-0013 - Loss of Normal Electrical Power
  • AW300-24-0038 - Nuisance "ELECTRICAL FAULT" CAS Message Upon Engine or APU Shut Down.

Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

NOTES:

Quick Links:

General Setup for Maintenance
Standard Aircraft Configuration for Maintenance AMM 12-00-00-867-803
Connect Electrical Power to the Aircraft AMM 24-00-00-861-801
Remove Electrical Power from the Aircraft AMM 24-00-00-861-802
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801
Electrostatic Discharge Safety Precautions AMM 24-00-00-910-802
Maintenance Tasks
Removal of the Main Generator AMM 24-31-05-000-801
Installation of the Main Generator AMM 24-31-05-400-801
Removal of the Generator Control Unit (GCU) - Primary AMM 24-31-13-000-801
Installation of the Generator Control Unit (GCU) - primary AMM 24-31-13-400-801
Removal of the Generator Power Module AMM 24-31-21-000-801
Installation of the Generator Power Module AMM 24-31-21-400-801
Removal of the DC Power Center (DCPC) AMM 24-61-01-000-801
Installation of the DC Power Center (DCPC) AMM 24-61-01-400-801

Troubleshooting Recommendations:

  1. Inspect the Generator Cooling Inlet and Outlet on the engine cowling for obstruction or debris.
  2. Verify that the Generator electrical connections are secured and in good condition.
  3. Spin the Left Generator (G1) shaft by hand through the opening of the cooling ports. Does it spin freely?

    1. If YES (the shaft is sheared), replace the defective Generator.
    2. If NO (some friction could be felt), continues with next step.

  4. Do wiring check of the following wires:

    From To Results
    L GEN conn. G1P1 - pin A L DCPC conn. A35P1 - pin F
    L GEN conn. G1P1 - pin B L DCPC conn. A35P1 - pin G
    L GEN conn. G1P1 - pin G L DCPC conn. A35P1 - pin AA
    L GEN conn. G1P1 - pin D L DCPC conn. A35P1 - pin H
    L GEN conn. G1P1 - pin F L DCPC conn. A35P1 - pin h
    L GEN conn. G1P1 - pin E L DCPC conn. A35P1 - pin J
    L GEN conn. G1P1 - pin L L DCPC conn. A35P1 - pin JJ
    L GEN conn. G1P1 - pin M L DCPC conn. A35P1 - pin z
    L GEN conn. G1P1 - pin H L DCPC conn. A35P1 - pin D
    L GEN conn. G1P1 - pin J L DCPC conn. A35P1 - pin d
    L GEN conn. G1P1 - pin K L DCPC conn. A35P1 - pin E

    1. If wiring check is satisfying, continue with next step.
    2. If wiring check is not satisfying, repair the defective wire.

  5. Interchange the Left Generator (G1) with the Right Generator (G2). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Generator.

  6. Interchange the Left Generator Control Unit (PCB5) with the Right Generator Control Unit (PCB6). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Generator Control Unit.

  7. Interchange the Left Generator Power Module (PCB7) with the Right Generator Power Module (PCB8). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Generator Power Module.

  8. Replace Left DC Power Center (A35).
  9. Do close out.