Message Overview:
Message Description:
The Right APU Generator Contactor 1 (RAPC1) has failed.
Possible Causes:
- Right APU Generator Contactor (RAPC1) (K72)
- Auxiliary Power Center Primary Logic (ALOG) (PCB11)
- Auxiliary Power Center (Aux DCPC) (A196)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-24-0024 - Electrical System - Troubleshooting Tips
- AW300-24-0137 - Y06 Electrical System Upgrade
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Auxiliary Power Center (Aux DCPC) | AMM 24-64-01-000-801 |
| Installation of the Auxiliary Power Center (Aux DCPC) | AMM 24-64-01-400-801 |
| Removal of the Auxiliary DC Power Contactor | AMM 24-64-05-000-801 |
| Installation of the Auxiliary DC Power Contactor | AMM 24-64-05-400-801 |
| Removal of the Auxiliary Power Center Primary Logic | AMM 24-64-13-000-801 |
| Installation of the Auxiliary Power Center Primary Logic | AMM 24-64-13-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Disconnect the Right Auxiliary DC Power Contactor K72 (RAPC1) connector located in the AUX DCPC (A196). Do visual inspection of the connector and associated wiring for any loose pins and/or damaged wire.
- If inspection is satisfying, continue with next step.
- If inspection is not satisfying, go to step 5.
- Verify Right Auxiliary DC Power Contactor K72 (RAPC1) coils by measuring the resistances at the contactor connector as per the following table:
Coils Expected Values Results (Pick-up) Pin 1 and Pin 2 between 4.5 Ω and 6.5 Ω (Hold) Pin 2 and Pin 3 between 260 Ω and 280 Ω - If the verification is satisfying, continue with next step.
- If the verification is not satisfying, replace the defective Auxiliary DC Power Contactor.
NOTE: It is important to not skip this verification before proceeding with the interchange at step 3. A short of one of the 2 coils will result with a blowing of a fuse on the Auxiliary Power Center Primary Logic PC11.
- Interchange the Right Auxiliary DC Power Contactor K72 (RAPC1) with the Left Auxiliary DC Power Contactor K71 (LAPC1). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Auxiliary DC Power Contactor.
- Replace the Auxiliary Power Center Primary Logic PC11. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the Aux DCPC (A196).
- Do close out.