Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/25/21

Message Overview:

Message Name:

FAULT

Message Code:

B3-007766

Associated CAS:

R GEN FAIL
(Caution)

Reporting LRU: R GEN GCU
System Description: 24-31-00
24-61-00
Schematic Diagram: 24-31-00
24-61-00
Wiring Diagram: 24-31-07
24-31-15
24-61-03

Message Description:

The Right Generator Control Unit (RGCU) has failed.

Possible Causes:

  • Right Generator Control Unit (RGCU) (PCB6)
  • Right Generator Power Module (RGPM) (PCB8)
  • Right Generator (RGEN) (G2)
  • Right DC Power Center (RDCPC) (A36)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW300-24-0013 - Loss of Normal Electrical Power
  • AW300-24-0038 - Nuisance "ELECTRICAL FAULT" CAS Message Upon Engine or APU Shut Down.
  • AW300-24-0115 - Introduction of Improved Generator P/N A3579-102
  • AW300-24-0132 - Power Module (PMOD) P/N R3608-011 - Generator Failures at High Engine Speed
  • AW300-24-0137 - Y06 Electrical System Upgrade
  • AW300-24-0162 - Service Bulletin 100-24-20 - DC Power Center (DCPC) System - Inspection and Replacement of Internal Fuses in the L/H and R/H DC Power Center (DCPC)

Forum Articles/Infoservice/Newsletter: None

NOTE: If the MDC is reporting multiple GEN GCU fault messages simultaneously, accompanied by a Proximity Sensing Electronics Unit (PSEU) failure, most likely B3-007551 - PSEU SYSTEM FAILURE or B3-007550 - PSEU OFF/NO OUTPUT, the ATA 32 fault(s) must be addressed first.

NOTE: For troubleshooting purposes you may refer to the Generators Windings Values table.

Quick Links:

Removal of the Main Generator AMM 24-31-05-000-801
Installation of the Main Generator AMM 24-31-05-400-801
Operational Test of the Main Generator AMM 24-31-05-710-801
Removal of the Generator Control Unit (GCU) - Primary AMM 24-31-13-000-801
Installation of the Generator Control Unit (GCU) - primary AMM 24-31-13-400-801
Removal of the Generator Power Module AMM 24-31-21-000-801
Installation of the Generator Power Module AMM 24-31-21-400-801
Removal of the DC Power Center (DCPC) AMM 24-61-01-000-801
Installation of the DC Power Center (DCPC) AMM 24-61-01-400-801
Functional Test of the DC Power Center (DCPC) AMM 24-61-01-720-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Swap the Right Generator Control Unit (PCB6) with the Left Generator Control Unit (PCB5). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Generator Control Unit.
      NOTE: Whilst the card is removed, inspect the card contacts and make sure they are clean and free from contamination.

  2. Swap the Right Generator Power Module (PCB8) with the Left Generator Power Module (PCB7). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Generator Power Module.

  3. Perform a wiring check between the right Generator (GEN 2) and the right DC Power Center (A36) as follows:

    From To Results
    G2P1-A A36P1-F
    G2P1-B A36P-G
    G2P1-G A36P1-AA
    G2P1-D A36P1-H
    G2P-F A36P1-h
    G2P1-E A36P1-J
    G2P1-L A36P1-JJ
    G2P1-M A36P1-z
    G2P1-H A36P1-D
    G2P1-J A36P1-d
    G2P1-K A36P1-E

    1. If wiring defects are found, repair defective wiring as required and do close out.
    2. If no defects are found, continue with next step.

  4. Swap the Right Generator (G2) with the Left Generator (G1). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Generator.

  5. Replace Right DC Power Center (A36).
  6. Do close out.