06/29/24
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ABNORM 2-7 |
| System Description: | 21-31-00 |
| Schematic Diagram: | 21-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-31-07 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The pressurization control does not operate correctly.
Possible Causes:
- Air Data Computer (ADC) 1
- Air Data Computer (ADC) 2
- Cabin Pressure Controller (CPC) 1
- Cabin Pressure Controller (CPC) 2
- Data Acquisition Unit (DAU) 3
- Data Acquisition Unit (DAU) 4
- Interface Wiring between DAUs and CPCs
- Interface Wiring between the Outflow Valves and the CPCs
- Outflow Valve 1
- Outflow Valve 2
- Safety Valve 1
- Safety Valve 2
- Interface Wiring between ADCs and CPCs
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Cabin Pressure Controllers | AMM 21-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Cabin Pressure Controllers | AMM 21-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Select related CAIMS message below: