Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ENVR 06-12 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-60-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The pack discharge temperature is out of range when the flow control valve is not closed and there is no R PACK FAIL message.
Possible Causes:
- PACK Discharge Pressure Sensor (PDPS) 2 (MT107)
- Air Cycle Machine (ACM)
- HOT/COLD Toggle Switch (S4)
- BLEED AIR Control Panel (AP8)
- Air-Conditioning System Controller (ACSC) 2 (A88)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Air Cycle Machines | AMM 21-52-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air Cycle Machines | AMM 21-52-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Pack Discharge Temperature-Sensors | AMM 21-52-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Pack Discharge Temperature-Sensors | AMM 21-52-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Anti-Icing Pressure Sensors | AMM 21-52-41-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Anti-Icing Pressure Sensors | AMM 21-52-41-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the BLEED-AIR Control Panel | AMM 36-11-57-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the BLEED-AIR Control Panel | AMM 36-11-57-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Switches and Potentiometers - Removal/Installation | SPM 20-11-01-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access CAIMS active and stored faults. Are there any air conditioning (ATA 21) related fault messages?
- If YES, troubleshoot these messages first using SmartFix Plus CAIMS troubleshooting pages.
- If NO, continue with next step.
- Make sure the aircraft is parked inside away from direct sunlight and has been allowed to reach ambient temperature before continuing with next step.
- Access CAIMS System Diagnostics. Select ATA 21, ACSC 1A, LRU TEST and select L ACSC CH.A PACK TEMP SENSOR DATA. Record the data on the ECS Data Table. Repeat for ACSC 1B, 2A and 2B.
- To record all of the data you will also need to look at ATA 36, BMC 1(2), L BMC DISCRETE & ANALOG INPUT DATA.
- Follow the instructions comprised in the Pack Discharge Temperature Split troubleshooting document.
- If the root cause of the issue has been identified and rectified, do close out.
- If the issue persists, continue with next step.
- Swap ACSC 2 (A88) with ACSC 1 (A87). Is the fault still present on the same side?
- If YES, continue with next step.
- If NO, replace defective ACSC.
- On the BLEED AIR control panel, perform a continuity checks of HOT/COLD toggle switch as follows:
HOT/COLD toggle switch position From To Expected result Result COLD position AP8J2-25 AP8J2-3 Continuity COLD position AP8J2-26 AP8J2-3 Open HOT position AP8J2-25 AP8J2-3 Continuity HOT position AP8J2-26 AP8J2-3 Open - If the toggle switch operates as per table above, continue with next step.
- If the toggle switch is found faulty, replace the HOT/COLD toggle switch and do close out.
- Remove ACSC 2 (A88) and perform a continuity check from the BLEED AIR control panel aircraft-side connector as follows:
From To Result AP8P2-25 Ground AP8P2-26 Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Replace BLEED AIR control panel. Is the fault still present?
- If YES, contact the Bombardier Customer Response Center and provide the ECS Data Table previously populated for further assistance.
- If NO, continue with next step.
- Do close out.