07/08/19
Message Overview:
| DDG Reference: | TC Only |
| Pilot Action (QRH): | ABNORM 2-4 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-60-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
When one or more of the conditions that follow occur:
- The temperature of the distribution duct is above 90°C (194°F) for 30 seconds
- The temperature of the distribution duct is above 120°C (248°F) for 10 seconds with the emergency pressurization on OR
- Both the trim-air leak-detection loops are defective
Possible Causes:
- Hot air shut-off valves is failed in either the closed position or the open position.
- Trim Air Valve
- Duct Temperature Sensor
- Trim Air Leak Detection Loop
- Air-Conditioning System Controllers (ACSCs)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Ventilated Temperature Sensors | AMM 21-60-25-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Ventilated Temperature Sensors | AMM 21-60-25-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Duct Temperature Sensors | AMM 21-60-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Duct Temperature Sensors | AMM 21-60-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Air Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Air Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations: