01/29/21
Message Overview:
| DDG Reference: | CAS-33 |
| Pilot Action (QRH): | ENVR 06-18 |
| System Description: | 21-54-00 |
| Schematic Diagram: | 21-54-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-54-15 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Air Conditioning System Controller (ACSC) 2 senses that the Avionics Exhaust Fan or Avionics Exhaust-Fan Converter is defective.
Possible Causes:
- Avionics Exhaust Fan (B62)
- Avionics Exhaust-Fan Converter (B29)
- Air Conditioning System Controller (ACSC) 2 (A88)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Avionics Exhaust Fan | AMM 21-54-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Avionics Exhaust Fan | AMM 21-54-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Avionics Exhaust−Fan Converter | AMM 21-54-41-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Avionics Exhaust−Fan Converter | AMM 21-54-41-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access CAIMS to view Active/Stored Faults. Select displayed message from menu below:
- Do close out.