07/08/19
Message Overview:
| DDG Reference: | 21-71 |
| Pilot Action (QRH): | ADVISORY 2-2 |
| System Description: | 21-70-00 |
| Schematic Diagram: | 21-71-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-71-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The humidifier becomes defective.
Possible Causes:
- Humidifier Level Sensor (MT214)
- Humidifier Cabin Humidity Sensor (HCHS) (MT215)
- Humidifier Water Boiler Temperature Sensor (HWTBS) (MT213)
- Humidifier Drain Valve (HDV) (L53)
- Humidifier Trim Air Valve (HTAV)
- Humidifier Water Feed Valve (HWFV (L52))
- Humidifier Water Shut-off Valve (HWSOV) (L51)
- Aircraft Water Supply
- Ground Stud GS257 incorrectly installed
- Junction Box 3 (JB3)
- Junction Box 4 (JB4)
- Secondary Power Distribution Assembly (SPDA) 2
- Air Conditioning System Controller (ACSC) 2
- Humidifier Control Unit (HCU)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of Humidifier Control Unit | AMM 21-71-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Humidifier Control Unit | AMM 21-71-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Humidifier Cabin Humidity Sensor | AMM 21-71-49-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Humidifier Cabin Humidity Sensor | AMM 21-71-49-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Function Test of the Humidifier System | AMM 21-71-00-720-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |