background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/08/19

Message Overview:

HUMIDIFIER FAIL
(Advisory)

DDG Reference: 21-71
Pilot Action (QRH): ADVISORY 2-2
System Description: 21-70-00
Schematic Diagram: 21-71-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-71-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The humidifier becomes defective.

Possible Causes:

  • Humidifier Level Sensor (MT214)
  • Humidifier Cabin Humidity Sensor (HCHS) (MT215)
  • Humidifier Water Boiler Temperature Sensor (HWTBS) (MT213)
  • Humidifier Drain Valve (HDV) (L53)
  • Humidifier Trim Air Valve (HTAV)
  • Humidifier Water Feed Valve (HWFV (L52))
  • Humidifier Water Shut-off Valve (HWSOV) (L51)
  • Aircraft Water Supply
  • Ground Stud GS257 incorrectly installed
  • Junction Box 3 (JB3)
  • Junction Box 4 (JB4)
  • Secondary Power Distribution Assembly (SPDA) 2
  • Air Conditioning System Controller (ACSC) 2
  • Humidifier Control Unit (HCU)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of Humidifier Control Unit AMM 21-71-17-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of Humidifier Control Unit AMM 21-71-17-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of Humidifier Cabin Humidity Sensor AMM 21-71-49-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of Humidifier Cabin Humidity Sensor AMM 21-71-49-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Function Test of the Humidifier System AMM 21-71-00-720-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.