07/08/19
Message Overview:
| DDG Reference: | 21-51-02 |
| Pilot Action (QRH): | ADVISORY 2-2 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-53-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-52-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Ram air system does not operate.
Possible Causes:
- Ram Air Valve (L25)
- Right Air Conditioning System Controller (ACSC) (A88)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Ram Air Valve | AMM 21-53-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Ram Air Valve | AMM 21-53-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |