Message Overview:
| DDG Reference: | 21-21 |
| Pilot Action (QRH): | ADVISORY 2-2 |
| System Description: | 21-20-00 |
| Schematic Diagram: | 21-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Indicates when both recirculation fans are inoperative.
The EICAS message "RECIRC FAN FAIL" comes on if both Air-Conditioning System Controllers (ACSC) 1 and 2 report this fault. WHEN bit 29 label 271 = 1 from ACSC1 AND bit 29 label 271 = 1 from ACSC2.
Possible Causes:
- Left/Right Air Conditioning System Controller (ACSC)
- Left/Right Recirculation Fan
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of Air Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Air Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Recirculation Fan and Check Valves | AMM 21-21-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Recirculation Fan and Check Valves | AMM 21-21-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations: