10/12/23
Message Overview:
| DDG Reference: | TC Only |
| Pilot Action (QRH): | ENVR 06-24 |
| System Description: | 21-60-00 - Temperature Control |
| Schematic Diagram: | [ G5000 ] [ Global Express ] [ Global XRS ] SSM 21-60-00-101 - Air Conditioning Temperature Control System - Electrical Schematic |
| Wiring Diagram: | [ G5000 ] [ Global Express ] [ Global XRS ] WM 21-60-00-1_001 - Sheet 1 - ACS Control (Left) [ G5000 ] [ Global Express ] [ Global XRS ] WM 21-60-00-1_001 - Sheet 1 - ACS Control (Left) - [9004-9010] |
Message Description:
There is a problem with the trim air or when the temperature of the distribution duct is too high.
Possible Causes:
- Hot Air Shut-off valves is failed in either the closed position or the open position
- Trim Air Valve
- Duct Temperature Sensor
- Trim Air Leak Detection Loop
- Air Conditioning System Controllers (ACSC)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-36-0826 - Kidde Bleed Leak Detection Loops Notice of Escape
Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Removal of the Duct Temperature Sensors | [ G5000 ] [ Global Express ] [ Global XRS ] AMM21-60-17-000-801 |
| Installation of the Duct Temperature Sensors | [ G5000 ] [ Global Express ] [ Global XRS ] AMM21-60-17-400-801 |
| Removal of the Air-Conditioning System Controllers | [ G5000 ] [ Global Express ] [ Global XRS ] AMM21-60-21-000-801 |
| Installation of the Air-Conditioning System Controllers | [ G5000 ] [ Global Express ] [ Global XRS ] AMM21-60-21-400-801 |
| Removal of the Ventilated Temperature Sensors | [ G5000 ] [ Global Express ] [ Global XRS ] AMM21-60-25-000-801 |
| Installation of the Ventilated Temperature Sensors | [ G5000 ] [ Global Express ] [ Global XRS ] AMM21-60-25-400-801 |
| Wire Repair - Maintenance Practices - ALL | [ G5000 ] [ Global Express ] [ Global XRS ] SPM20-12-10-02 |
Troubleshooting Recommendations:
- Select a fault message below:
- Do the close out.