07/08/19
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | STATUS-1 |
| System Description: | 21-31-00 |
| Schematic Diagram: | 21-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-31-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
CAS message displayed when cabin pressure rate is not set to HIGH on the PRESSURIZATION control panel.
Possible Causes:
- RATE Toggle Switch
- PRESSURIZATION Control Panel (AP9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the PRESSURIZATION Control Panel | AMM 21-31-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the PRESSURIZATION Control Panel | AMM 21-31-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between PRESSURIZATION Control Panel and CPCs or a short circuit to ground.
AP9P1 (PRESSURIZATION PANEL) A21P1 (CABIN PRESSURE
CONTROLLER 1)pin 36 pin 26 AP9P1 (PRESSURIZATION PANEL) A22P1 (CABIN PRESSURE
CONTROLLER 2)pin 13 pin 26 - If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace PRESSURIZATION Control Panel.
- Do close out.