07/08/19
Message Overview:
| DDG Reference: | 21-62-08 |
| Pilot Action (QRH): | STATUS-1 |
| System Description: | 21-31-00 |
| Schematic Diagram: | 21-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-31-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
CAS message displayed when OUTFLOW VALVE 1 PBA is not pushed in.
Possible Causes:
- OUTFLOW VALVE 1 Pushbutton (SDS2)
- PRESSURIZATION Control Panel (AP9)
- Data Acquisition Unit (DAU) 1 (A17)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the PRESSURIZATION Control Panel | AMM 21-31-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the PRESSURIZATION Control Panel | AMM 21-31-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the PRESSURIZATION control panel, make sure that the OUTFLOW VALVE 1 pushbutton switch is not pushed in.
- Swap PBAs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap DAUs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between DAU1 and PRESSURIZATION Control Panel or a short circuit to ground.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace PRESSURIZATION Control Panel.
- Do close out.