07/08/19
Message Overview:
| Reporting LRU: | None |
| Pilot Action (QRH): | None |
| System Description: | 21-52-00 |
| Schematic Diagram: | 21-52-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-52-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The PACK CONTROL rotary switch on the BLEED AIR control panel is set to the HIGH position.
Possible Causes:
- PACK CONTROL Rotary Switch/BLEED AIR Control Panel
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Rotary Switch/Potentiometer | AMM 20-11-01-000-806 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Rotary Switch/Potentiometer | AMM 20-11-01-400-806 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Air Control Panel | AMM 36-11-57-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Air Control Panel | AMM 36-11-57-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the BLEED AIR control panel, make sure that the PACK CONTROL rotary switch is not set to the HIGH position.
- On BLEED AIR control panel connector AP8J2 perform wiring checks between pin 52 and pin 3 (DC2 RTN).
- If continuity, go to step 4.
- If no continuity, continue with next step.
- On BLEED AIR control panel connector AP8J2 perform wiring checks between pin 52 and ground.
- If continuity, go to step 5.
- If no continuity, go to step 6.
- Replace PACK CONTROL rotary switch
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace BLEED AIR control panel.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Repair or replace the interface wiring.
- Do close out.