03/08/21
Message Overview:
| DDG Reference: | 26-12-01 |
| Pilot Action (QRH): | ABNORM 7-2 |
| System Description: | 26-12-00 |
| Schematic Diagram: | 26-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 26-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
There is a failure of the two fire detection loops from APU engine.
Possible Causes:
- Fire Detection and Extinguishing (FIDEEX) Control Unit (CU)
- Auxiliary Power Unit (APU) Loop A
- Auxiliary Power Unit (APU) Loop B
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Removal of the Fire Detection and Extinguishing (FIDEEX) Control Unit | AMM 26-10-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fire Detection and Extinguishing (FIDEEX) Control Unit | AMM 26-10-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Eductor Sensing Elements | AMM 26-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Eductor Sensing Elements | AMM 26-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Hatch Sensing Elements | AMM 26-12-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Hatch Sensing Elements | AMM 26-12-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Strut Sensing Elements | AMM 26-12-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Strut Sensing Elements | AMM 26-12-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |