06/09/21
Message Overview:
| DDG Reference: | 26-12 |
| Pilot Action (QRH): | SMK 14-02-21 |
| System Description: | 26-21-00 |
| Schematic Diagram: | 26-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 26-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Fire extinguisher bottle #2 pressure is below 250 ±25 psig.
Possible Causes:
- Fire extinguisher bottle 2 pressure is low.
- Fire Extinguisher Bottle 2 Pressure Switch
- Fire Detection and Extinguishing (FIDEEX) Control Unit (CU)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
NOTE: If the Fire Bottle was completely discharged with no activation of the Fire Handle, refer to this Observed Fault.
Quick Links:
| Removal of the Fire Detection and Extinguishing (FIDEEX) Control Unit | AMM 26-10-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fire Detection and Extinguishing (FIDEEX) Control Unit | AMM 26-10-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Fire Extinguisher Container | AMM 26-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fire Extinguisher Container | AMM 26-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access CAIMS to view active or stored faults. Select displayed message from menu below:
- If no message is displayed, continue with next step.
- Check the gauge pressure indication on the FIREX bottle.
- If gauge shows an indication of 250 ±25 psi (1724 ±172 Pa) or less, go to step 4.
- If not, continue with next step.
- Disconnect Fire Extinguisher Container connector A112P4 and FIDEEX control unit connector A106P2. Perform a continuity check as follows:
From To Expected Result Result A112P4-3 Ground Open A112P4-2 Ground Open A112P4-3 A106P2-50 Continuity A112P4-2 A106P2-40 Continuity - If wiring defects are found, repair defective associated wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace the Fire Extinguisher Container. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the FIDEEX control unit.
- Do close out.