07/16/19
Message Overview:
| DDG Reference: | 26-15-01 |
| Pilot Action (QRH): | ABNORM 7-3 |
| System Description: | 26-14-00 |
| Schematic Diagram: | 26-14-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 26-10-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Smoke Detectors 1 and/or 2 are defective.
Possible Causes:
- Fire Detection and Extinguishing (FIDEEX) Control Unit (CU)
- Smoke Detector 1
- Smoke Detector 2
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Fire Detection and Extinguishing (FIDEEX) Control Unit | AMM 26-10-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fire Detection and Extinguishing (FIDEEX) Control Unit | AMM 26-10-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Baggage Compartment Smoke Detector | AMM 26-14-04-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Baggage Compartment Smoke Detector | AMM 26-14-04-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Data Acquisition Unit (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Data Acquisition Unit (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |