07/16/19
Message Overview:
| DDG Reference: | 26-16-01 |
| Pilot Action (QRH): | ABNORM 7-3 |
| System Description: | 26-14-00 |
| Schematic Diagram: | 26-14-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 26-10-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Smoke Detector 3 is defective.
Possible Causes:
- Smoke Detector 3
- Fire Detection and Extinguishing (FIDEEX) Control Unit (CU)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Fire Detection and Extinguishing (FIDEEX) Control Unit | AMM 26-10-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fire Detection and Extinguishing (FIDEEX) Control Unit | AMM 26-10-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AFT LAV Compartment Smoke Detectors | SMM 26-14-52-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of FWD LAV Compartment Smoke Detectors | SMM 26-14-52-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Measure for 28 VDC at Smoke Detector #3 (A115P1).
- If there is 28 VDC, go to step 4.
- If there is no 28 VDC, continue with next step.
- Perform wiring check between FIDEEX CU (A106P1) and Smoke Detector 3 (A115P1). Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace FIDEEX CU.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Smoke Detector 3.
- Do close out.