08/23/23
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ABNORM 8-10 |
| System Description: | 27-50-00 - Slats and Flaps System |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-07 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The slats and flaps do not operate because of a latched fault. The slats and flaps cannot be selected.
NOTE: The SLAT FAIL (Amber) message or the FLAP FAIL (Amber) message shows when the fault affects only one system.
Possible Causes:
- Slat Flap Control Unit (SFCU)
- A mechanical jam in the drive line (after third try to move the system)
- Loss of power to the system
- Overheated components
- There is a skew trip of the flaps
- There is a mechanical disconnect
- There is a system overspeed condition
- The SFCS is not rigged correctly
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-27-0373 - SFCU -17: "SLAT-FLAP HALFSPD" EICAS Nuisance Message
Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
NOTE 1: If an SFCU seems to be in a locked up state, please refer to this Troubleshooting Tip for more information and instructions to resolve the issue.
NOTE 2: To avoid the display of any Slat/Flap related CAS nuisance message after replacement of SFCU due to internal failure, follow AW 700-27-0373 instructions.
- Execute two consecutive Slats and Flaps electrical rigging on CAIMS (All EICAS messages and CAIMS Active faults related to the Slat Flap Control System must be disregarded throughout the dual electrical CAIMS rigging process.)
- Once the two CAIMS SFCS rigging are completed, perform a complete aircraft power shut down
Quick Links:
| Removal of Slat Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Slat Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Rigging of flap system | AMM 27-52-00-820-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Rigging of leading edge slat system | AMM 27-53-00-820-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access the Active Faults/Stored Faults as per AMM Tasks.
- Select related CAIMS message below:
- Do the close out.