08/02/24
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ABNORM 8-4 |
| System Description: | 27-40-00 |
| Schematic Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-00 AC Load Distribution AC Power Center (ACPC) System [ Global Express ] [ G5000 ] [ Global XRS ] 24-52-00 AC Load Distribution Cockpit Circuit Breaker Panel (CCBP) System [ Global Express ] [ G5000 ] [ Global XRS ] 27-41-00 Horizontal Stabilizer Pitch Trim System |
| Wiring Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-00 ACPC Distribution Left [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-00 ACPC Distribution Right [ Global Express ] [ G5000 ] [ Global XRS ] 24-52-01 Cockpit Circuit Breaker Panel (CCBP) [ Global Express ] [ G5000 ] [ Global XRS ] 27-41-01 Pitch Trim System Control |
Message Description:
The pitch trim function is not available because of problems with the two pitch trim channels.
Possible Causes:
- Flight Control Unit (FCU)
- Master Disconnect (MASTER DISC) Switch on a Handwheel
- Horizontal-Stabilizer Motor Drive Unit
- Horizontal-Stabilizer Actuator
- STAB PUSH OFF/RESET Pushbutton Annunciator on the TRIMS Control Panel
- Pitch Trim (NOSE DN or NOSE UP) Switch on the Handwheel
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM):
- [ Global Express ] [ G5000 ] [ Global XRS ] FON 01-11 FCLT-004 [STAB CH1 FAIL] (Advisory/Cyan) or [STAB CH2 FAIL] (Advisory/Cyan) or [STAB TRIM] (Cyan/Amber) On Ground
NOTES:
- To support a NFF technical investigation please fill out this Questionnaire and send it to your FSR if you are replacing a Flight Control Unit (FCU).
- Verify C/B status on both pilot and copilot EMS CDUs. This CAS Message will post if both circuit breakers or Smart Contactor status is OUT or Tripped.
| LOCATION | CB NO. | NAME |
|---|---|---|
| ACPC (A35) | CB-B6 | STAB CH1 |
| CCBP (A54) | CB-E5 | STAB CH2 |
| ACPC (A35) | SC-K15 | AC 1 FEED |
Quick Links:
| Removal of SFCU | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of SFCU | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Pitch Trim Actuator Motor | AMM 27-41-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Pitch Trim Actuator Motor | AMM 27-41-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Pitch Trim Actuator Motor Drive Unit | AMM 27-41-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Pitch Trim Actuator Motor Drive Unit | AMM 27-41-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Pitch Trim Switches | AMM 27-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Pitch Trim Switches | AMM 27-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access the CAIMS to view fault messages. Select displayed message from menu below: