background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

08/23/23

Message Overview:

FLAP DRIVE OVHT
(Advisory)

DDG Reference: None
Pilot Action (QRH): ADVISORY 7-2
System Description: 27-50-00 - Slats and Flaps System
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-07 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

There is an overheat condition in one or the two PDU motors or SFCUs.

Possible Causes:

  • Slat Flap Control Unit (SFCU)
  • Flap PDU Motor
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

NOTE:

  • The FLAP FAIL (Amber) message also shows when there is an overheat condition on the two channels and the flaps do not operate
  • The FLAP HALFSPD (Cyan) message also shows when there is an overheat condition on a single channel and the flaps operate at half speed

Quick Links:

Removal of Slat Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of Slat Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of Flap Power Drive Unit (PDU) Motors AMM 27-52-41-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of Flap Power Drive Unit (PDU) Motors AMM 27-52-41-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Using the PMAT, access the Active Faults/Stored Faults as per AMM Tasks.
  2. Select related CAIMS message below:
  3. Do the close out.