08/23/23
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ADVISORY 7-2 |
| System Description: | 27-50-00 - Slats and Flaps System |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-07 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
An overheat condition in one or the two Power Drive Unit (PDU) motors or Slat Flap Control Unit (SFCU)s.
NOTE:
- The SLAT FAIL (Caution) message also shows when there is an overheat condition on the two channels and the slats do not operate
- The SLAT HALFSPD (Cyan) message also shows when there is an overheat condition on a single channel and the slats operate at half speed
Possible Causes:
- Slat Flap Control Unit (SFCU)
- Slat Power Drive Unit (PDU) Motor
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Removal of Slat Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Slat Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Slat Power Drive Unit (PDU) Motors | AMM 27-53-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Slat Power Drive Unit (PDU) Motors | AMM 27-53-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access the Active Faults/Stored Faults as per AMM Tasks.
- Select related CAIMS message below:
- Do the close out.