07/18/19
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | STATUS-2 |
| System Description: | 27-40-00 |
| Schematic Diagram: | 27-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-41-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Horizontal stabilizer channel 1 is OFF. To push the applicable STAB CH1 PUSH OFF/RESET pushbutton annunciator causes the channel to turn OFF. It also causes the OFF legend of the PBA to come on.
Possible Causes:
- Flight Control Unit (FCU)
- STAB 1 PUSH OFF/RESET Pushbutton Annunciator is pushed
- STAB 1 PUSH OFF/RESET PBA
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of Flight Control Unit | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Flight Control Unit | AMM 27-61-05-400-801 [Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of AIL/RUD/STAB TRIMS Control Panel | AMM 27-12-01-000-801 [Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of AIL/RUD/STAB TRIMS Control Panel | AMM 27-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Select related CAIMS message below.