Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/19/19

Message Overview:

AFT FUEL XFER OFF
(Status)

DDG Reference: 28-22-03
Pilot Action (QRH): STATUS-2
System Description: 28-22-00
Schematic Diagram: 28-22-00 [ Global Express ]  [ Global XRS ]
Wiring Diagram: 28-22-00 [ Global Express ]  [ Global XRS ]

Fault Description:

AFT FUEL XFER OFF (status) shows when the AFT XFER switch on the FUEL control panel is set to OFF.

This troubleshooting applies when it is not under normal conditions.

NOTE: This troubleshooting sheet does not apply to the Global 5000.

Possible Causes:

  • AFT XFER Switch (S2)
  • Fuel Management and Quantity Gauging Computer (FMQGC)
  • Ground Stud (GS884)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Fuel Management and Quantity Gauging Computer AMM 28-41-01-000-801 [ Global Express ]  [ Global XRS ]
Installation of the Fuel Management and Quantity Gauging Computer AMM 28-41-01-400-801 [ Global Express ]  [ Global XRS ]
Removal of the Fuel Control Panel (AP5) AMM 28-20-01-000-801 [ Global Express ]  [ Global XRS ]
Installation of the Fuel Control Panel (AP5) AMM 28-20-01-400-801 [ Global Express ]  [ Global XRS ]
Wire Repair SPM 20-12-10 [ Global Express ]  [ Global XRS ]

Troubleshooting Recommendations:

NOTE: The AFT FUEL XFER OFF (Status) CAS message does not display when AFT XFER knob is in the OFF position.

  1. Turn on aircraft power and access the CAIMS PMAT

    • Access CAIMS.
    • Select System Diagnostics.
    • Select 28-00 FUEL.
    • Select Computer (FMQGC CH A(B).
    • Select LRU TEST
    • Select Cockpit fuel panel data CH A(B)

  2. On the fuel control panel rotate the AFT TRANSFER KNOB to OFF.
  3. Does the PMAT show the Manual Transfer OFF: go to TRUE?

    1. If YES, then go to step 9.
    2. If NO, then continue with the next step.

  4. Gain access and remove the FMQGC and inspect the tray, connectors and pins. Make sure connector A47DP1 pin E13 is not damaged, bent and is secured properly into place.

    1. If the check is good, continue with the next step.
    2. If the check is not good, rectify/replace as necessary.

  5. Perform a wiring continuity check per table below:

    FROM TO EXPECTED RESULT RESULT
    A47DP1 - E13 Airframe Ground Continuity

    1. If the wiring check is good, then go to step 9.
    2. If the wiring check is not good, then continue with the next step.

  6. Remove the Fuel control panel (AP5), and disconnect AP5P2.
  7. Perform a wiring continuity check per the table below:

    SWITCH POSITION FROM TO EXPECTED RESULT RESULT
    OFF AP5J2 - 46 AP5J2 - 25 Continuity
    OFF AP5P2 - 25 Airframe ground Continuity

    1. If there is no continuity between AP5J2 - 46 and AP5J2 - 25, then suspect the AFT XFER SWITCH (S2).
    2. If there is no ground on AP5P2 - 25, then repair or replace wiring going to GS884 or GS884.
    3. If the wiring checks are good, go to next step.

  8. Perform the wiring continuity check per table below:

    FROM TO EXPECTED RESULT RESULT
    AP5P2 - 46 A47DP1 - E13 Continuity

    1. If the wiring check is good, continue with next step.
    2. If the wiring check is not good, then repair or replace wiring between the FMQGC and the Fuel Control Panel (AP5).

  9. Re-install or re-rack the FMQGC making sure it is fully and properly pushed into place. Is the fault still present?

    1. If YES, then continue with the next step.
    2. If NO, then do close out.

  10. Replace FMQGC.