07/22/19
Message Overview:
| DDG Reference: | 28-40-01 |
| Pilot Action (QRH): | STATUS-2 |
| System Description: | 28-21-00 |
| Schematic Diagram: | 28-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
R AUX PUMP OFF (Status) shows when the conditions that follow occur:
- The R WING FEED INHIBIT AUX PUMP switch on the FUEL control panel is set to "OFF".
- The right auxiliary-pump pressure is low.
This troubleshooting applies when it is not under normal conditions.
Possible Causes:
- R WING FEED INHIBIT AUX PUMP Switch (SDS5)
- Fuel Control Panel (AP5)
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
- Ground Stud (GS160)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Fuel Management and Quantity Gauging Computer (FMQGC) | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fuel Management and Quantity Gauging Computer (FMQGC) | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the fuel control panel (AP5) | AMM 28-20-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the fuel control panel (AP5) | AMM 28-20-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
The RH AUX PUMP OFF (Status) CAS does not display when the R WING FEED INHIB AUX PUMP switch is turned OFF.
- Turn ON aircraft power and the CAIMS PMAT.
- Access CAIMS.
- Select System Diagnostics.
- Select 28-00 Fuel.
- Select Computer (FMQGC CH A(B))
- Select LRU Test.
- Select Cockpit fuel panel data - CH A(B).
- Scroll through the pages and find Right AUX Pump Inhibit Panel Switch:
- On the Fuel control panel (AP5) select the R WING FEED INHIBIT AUX PUMP switch.
- Does the PMAT change from OFF to ON and ON to OFF?
- If the status changes, then go to step 11.
- If the status does not change, continue with the next step.
- Remove the FMQGC and inspect the tray, connectors and pins. Make sure connector A47DP1 - G15 is not damaged, bent and is secured properly into place.
- If the check is good, continue with the next step.
- If the check is not good, rectify/replace as necessary.
- Perform the wiring continuity test per the table below:
SWITCH POSITION FROM TO EXPECTED RESULT RESULT R AUX PUMP SW DEPRESSED (OFF) A47DP1 - G15 Airframe ground Continuity - If the wiring check is good, go to step 11.
- If the wiring check is not good, then continue with next step.
- Remove the fuel control panel (AP5), and disconnect AP5P2.
- Perform the wiring continuity test per the table below:
FROM TO EXPECTED RESULT RESULT AP5J2 - 18 AP5J2 - 48 Continuity AP5P2 - 18 Airframe Ground Continuity - If the wiring check from AP5J2 - 18 to AP5J2 - 48 is not good then suspect R WING FEED INHIBIT AUX PUMP switch (SDS5) or the Fuel Control Panel (AP5).
- If the wiring check from AP5P2 - 18 to airframe ground is not good then repair or replace wiring between fuel control panel and GS160 or GS160.
- If the wiring check is good then continue with the next step.
- Perform the wiring continuity test per the table below:
FROM TO EXPECTED RESULT RESULT AP5P2 - 48 A47DP1 - G15 Continuity - If the wiring check is good, continue with next step.
- If the wiring check is not good then repair or replace the wiring from the Fuel Control Panel to the FMQGC.
- Re-connect AP5P2 and re-install the Fuel Control Panel.
- Re-install or Re-rack the FMQGC making sure it is fully and properly pushed into place. Is the fault still present?
- If the CAS does not display, then go to next step.
- If the CAS displays, then do close out.
- Suspect the FMQGC (A47).
- Do close out.