Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/22/19

Message Overview:

R PRI PUMP OFF
(Status)

DDG Reference: 28-40-02
Pilot Action (QRH): STATUS - 3
System Description: 28-21-00
Schematic Diagram: 28-21-00  [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-41-08  [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

R PRI PUMPS OFF (Status) shows when the conditions that follow occur:

  • The R WING FEED INHIBIT PRI PUMPS switch on the FUEL control panel is set to OFF.
  • The right aft boost-pump pressure is low.
  • The right forward boost-pump pressure is low.

This troubleshooting applies when it is not under normal conditions.

Possible Causes:

  • R WING FEED INHIBIT PRI PUMPS Switch (SDS4)
  • Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
  • Fuel Control Panel (AP5)
  • Ground Stud (GS160)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Fuel Management and Quantity Gauging Computer (FMQGC) AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Fuel Management and Quantity Gauging Computer (FMQGC) AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the fuel control panel (AP5) AMM 28-20-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the fuel control panel (AP5) AMM 28-20-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

The R PRI PUMPS OFF (Status) CAS does not display when the R PRI PUMPS switch is turned "OFF".

  1. Turn ON aircraft power and the CAIMS PMAT.

    • Access CAIMS.
    • Select System Diagnostics.
    • Select 28-00 Fuel.
    • Select Computer (FMQGC CH A(B))
    • Select LRU Test.
    • Select Cockpit fuel panel data - CH A(B).

  2. Scroll through the pages and find Right Primary Pumps Panel Switch:
  3. On the Fuel control panel (AP5) select the R PRI PUMP switch.
  4. Does the pump status change from INHIB to ON and ON to INHIB on the CAIMS page?

    1. If the status changes, then go to step 10.
    2. If the status does not change, continue with the next step.

  5. Gain access to the FMQGC (A47) and remove FMQGC from the tray.
  6. Perform the wiring continuity test per the table below:

    SWITCH POSITION FROM TO EXPECTED RESULT RESULT
    R PRI PUMPS (OFF) A47DP1 - E15 Airframe Ground Continuity

    1. If the wiring check is good, go to step 10.
    2. If the wiring check is not good, then continue with next step.

  7. Remove the fuel control panel (AP5), disconnect AP5P2.
  8. Perform the wiring continuity test per the table below:

    FROM TO EXPECTED RESULT RESULT
    AP5J2 - 47 AP5J2 - 18 Continuity
    AP5P2 - 18 Airframe Ground Continuity

    1. If the wiring from AP5J2 - 47 to AP5J2 - 18 is not good, suspect the R PRIMARY FUEL PUMP Switch (SDS4), or the Fuel Control Panel.
    2. If the wiring from AP5P2 - 18 to airframe ground is not good then repair or replace wiring to GS160, or GS160.
    3. If the wiring check is good then continue with the next step.

  9. Perform the wiring continuity test per the table below:

    FROM TO EXPECTED RESULT RESULT
    AP5P2 - 47 A47DP1 - E15 Continuity

    1. If the wiring check is good go to next step.
    2. If the wiring check is not good then repair or replace wiring between Fuel Control Panel and FMQGC.

  10. Re-install or Re-rack the FMQGC making sure it is fully and properly pushed into place. Is the fault still present?

    1. If the CAS does not display, go to next step.
    2. If the CAS displays, then do close out.

  11. Suspect the FMQGC (A47).
  12. Do close out.