07/23/19
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ABNORM 10-8 |
| System Description: | 29-30-00 |
| Schematic Diagram: | 29-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 29-00-05 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
No. 3 hydraulic-system is less than 1800 psi.
Possible Causes:
- The hydraulic System Filter Manifold Pressure Transducer
- Data Acquisition Unit (DAU) 3
- AC Hydraulic Pump 3A
- AC Hydraulic Pump 3B
- Hydraulic quantity
- Hydraulic Fluid Filter Elements
- Hydraulic System Pressure Relief Valve (Filter Manifold)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Quantity Check of the Hydraulic Reservoir Fluid | AMM 12-12-00-610-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of No. 3 Hydraulic System Filter Manifold | AMM 29-13-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of No.3 Hydraulic System Filter Manifold | AMM 29-13-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of No. 3 Return Filter Element | AMM 29-13-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of No. 3 Return Filter Element | AMM 29-13-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of No. 3 Press Filter Element | AMM 29-13-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of No.3 Press Filter Element | AMM 29-13-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of No. 3 Case Drain Filter Element | AMM 29-13-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of No. 3 Case Drain Filter Element | AMM 29-13-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of No.3 ACMP | AMM 29-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of No.3 ACMP | AMM 29-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Hydraulic Temperature Transducers | AMM 29-33-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Hydraulic Temperature Transducers | AMM 29-33-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Ensure system is properly serviced.
- If low quantity found, service system and recheck system. If system checks are good, do a close out.
- If quantity is good, continue with next step.
- Operate 3A and 3B Hydraulic ACMPs independently. Confirm pump operation on Hydraulic Synoptic page.
- If pump(s) fail to operate, replace applicable pump and retest. If system checks are good, do a close out.
- If fault remains, continue with next step.
- Inspect system filter DPIs.
- If DPIs are tripped, replace associated filter(s) and recheck system. If system checks are good, do a close out.
- If DPIs are good, continue.
- Swap Hyd System No. 3 Transducer (MT146) and Hyd System No. 1 Transducer (MT140).
- If system checks are good, do a close out.
- If fault remains, continue with next step.
- Swap DAUs.
- If system checks are good, do a close out.
- If fault remains, continue with next step.
- Perform wiring check between No. 3 filter manifold transducer (MT146), DAU 3 and SPDA 3. Confirm 28 VDC input from SPDA 3 to transducer.
- If wiring fault found / repaired and message clears, do a close out.
- If no voltage is found, SWAP SPDA 3 and SPDA 2.
- If system checks are good, do a close out.
- Replace the No. 3 Hydraulic System Filters.
- If system checks are good, do a close out.
- If fault remains, continue with next step.
- Swap Hydraulic System Filter Manifolds 3 and 2.
- If system checks are good, do a close out.
- If fault remains, continue with next step.
- Accomplish Hydraulic System No. 3 Internal Leakage Check.
- Do close out.