Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

10/01/21

Message Overview:

HYD EDP 2A FAIL
(Advisory)

DDG Reference: None
Pilot Action (QRH): ADVISORY 9-2
System Description: 29-30-00
Schematic Diagram: 29-12-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 29-00-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

DAU 3 is reporting the Engine Driven Pump 2A at a pressure less than 2400 psi with the right engine running.

Possible Causes:

  • Quantity of Hydraulic Fluid
  • Engine Driven Pump (EDP) 2A
  • Data Acquisition Units (DAU) 3
  • Hydraulic Pressure-Switch 2A
  • Right Hydraulic Firewall Shut-off Valve not fully open
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Quantity Check of the Hydraulic Reservoir Fluid AMM 12-12-00-610-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of Engine-Driven Hydraulic Pumps AMM 29-12-01-710-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of the Firewall Hydraulic Shutoff Valves AMM 29-12-33-710-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of Hydraulic Firewall Shutoff Valve AMM 29-12-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of Hydraulic Firewall Shutoff Valve AMM 29-12-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of EDP AMM 29-12-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of EDP AMM 29-12-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of Hydraulic Pressure Switches AMM 29-31-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of Hydraulic Pressure Switches AMM 29-31-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Carry out a quantity check of the hydraulic system 2.
  2. Verify that the right engine firewall hydraulic shut-off valve is physically fully open.
  3. If the right engine firewall hydraulic shut-off valve is not fully open, do the operational test of the right engine firewall hydraulic shut-off valve and replace if necessary.
  4. Start the left engine and check the No. 2 Hydraulic system pressure.

    1. If pressure is good, go to step 6.
    2. If pressure is low, continue with next step.

  5. Replace the EDP 2.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  6. With the engines running, disconnect the EDP 2A pressure switch connector S37P1 and install a jumper between S37P1-A and S37P1-B.

    1. If message remains, go to step 8.
    2. If message goes away, continue with next step.

  7. Replace the pressure switch.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  8. Remove jumper and install connector S37P1.
  9. Swap DAU 3 with DAU 2.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  10. Do wiring checks between EDP 2A pressure switch and DAU 3 and repair as required.
  11. Do close out.