Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ABNORM 11-8 |
| System Description: | 30-31-00 |
| Schematic Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 27-32-00 Stall Protection System [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-00 AC Load Distribution AC Power Center (ACPC) System [ Global Express ] [ G5000 ] [ Global XRS ] 24-52-00 AC Load Distribution Cockpit Circuit Breaker Panel (CCBP) System. |
| Wiring Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 30-31-02 Heat Control System (Right) [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-00 ACPC Distribution Left [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-00 ACPC Distribution Right [ Global Express ] [ G5000 ] [ Global XRS ] 24-52-01 Cockpit Circuit Breaker Panel (CCBP) |
Message Description:
The HBMU senses an AOA sensor heat fail condition.
Possible Causes:
- Interface wiring between AOA2 HEATER (either Vane or Case) and Heater/Brake-Temperature Monitoring Unit (HMBU) 2
- Angle-of-Attack (AOA) 2 Heater
- Heater/Brake-Temperature Monitoring Unit (HMBU) 2
Troubleshooting Tips:
Advisory Wire/Service Bulletin:None
Forum Articles/Infoservice/Newsletter:None
Flight Operation Notifications Manual (FONM):
- [ Global Express ] [ G5000 ] [ Global XRS ] FON 01-16 ICE-002, [PITOT 1 (2) (3) HT FAIL] (Caution/Amber), [L (R) AOA HEAT FAIL] (Caution/Amber), [STBY PITOT HT] (Caution/Amber), [ICE DETECTOR FAULT] (Advisory/Cyan), [L (R) PROBE MON FAIL] (Advisory/Cyan) or [TAT HT 1 (2) (3) FAIL] (Advisory/Cyan) On Ground.
NOTES:
- Verify C/B status on both pilot and copilot EMS CDUs. This CAS Message will post if either of the following circuit breaker or Smart Contactor status is OUT or Tripped.
| LOCATION | CB NO. | NAME |
|---|---|---|
| CCBP (A54) | CB-H9 | R AOA HEAT A |
| ACPC (A35) | SC-K15 | AC 1 FEED |
Quick Links:
| Removal of Heater/Brake-Temperature Monitoring Unit (HMBU) | AMM 30-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Heater/Brake-Temperature Monitoring Unit (HMBU) | AMM 30-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Angle-of-Attack Sensors | AMM 27-32-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Angle-of-Attack Sensors | AMM 27-32-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check status of AC 1 FEED on EMS CDU, the AC 1 Feed being out or tripped can drive multiple CAS to post.
BUS > AC 1 > AC 1 FEED.- If AC 1 FEED CB is IN go to step 3.
- If AC 1 FEED CB is OUT, set to IN.
AC 1 FEED CB SYSTEM PHASE CAS CB-G6 ESS TRU 1 3 AC BUS 1 FAIL (Caution) CB-G3 EVS FAIRING HEAT 3 EVS HEAT FAIL (Caution) CB-G9 SLAT/FLAP PWR 1 3 SLAT-FLAP HALFSPD (Advisory) CB-H5 EVS WINDOW HEAT 1 EVS HEAT FAIL (Caution) CB-H6 A/T CTLR 1 A/T 1 FAIL (Advisory)
A/T 2 FAIL (Advisory)CB-H7 PITOT 1 HT A 1 PITOT 1 HT FAIL (Caution) CB-H8 R ICE DETECTOR 1 ICE DETECTOR FAULT (Advisory) CB-H9 R AOA HEAT A 1 R AOA HEAT FAIL (Caution) CB-H10 L WSHLD HEAT 1 1 L WSHLD HEAT FAIL (Caution) CB-H11 L WSHLD HEAT 2 1 R WSHLD HEAT FAIL (Caution) CB-G12 TRU BAY FAN 3 ELEC SYS FAULT (Advisory) CB-B6 STAB TRIM CH1 3 STAB CH 1 FAIL (Advisory) - Did the CAIMS Fault & CAS messages clear after setting AC 1 FEED CB to IN.
- If YES, do close out.
- If NO, go to next step.
- Perform wiring checks between HBMU2 and AOA2 Vane & Case heaters.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Measure the resistance of AOA2 Vane & Case heaters.
AOA vane heater = 30 ±10 ohms.
AOA case heater = 30 ±12 ohms.- If resistance within range, go to step 4.
- If resistance out of range, continue with next step.
- Replace AOA2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Interchange HBMUs.
- Do close out.