08/06/24
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ABNORM 11-8 |
| System Description: | 30-31-00 |
| Schematic Diagram: | 30-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-31-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The STBY PITOT STATIC probe heater circuit has been detected open circuit by HBMU 2.
Possible Causes:
- Standby Pitot Static Probe Heater
- Heater/Brake-Temperature Monitoring Unit (HBMU) 2
- Associated wiring between HBMU2 and Standby Pitot Static Probe
Troubleshooting Tips:
Advisory Wire/Service Bulletin:None
Forum Articles/Infoservice/Newsletter:None
Flight Operation Notifications Manual (FONM):
- [ Global Express ] [ G5000 ] [ Global XRS ] FON 01-16 ICE-002, [PITOT 1 (2) (3) HT FAIL] (Caution/Amber), [L (R) AOA HEAT FAIL] (Caution/Amber), [STBY PITOT HT] (Caution/Amber), [ICE DETECTOR FAULT] (Advisory/Cyan), [L (R) PROBE MON FAIL] (Advisory/Cyan) or [TAT HT 1 (2) (3) FAIL] (Advisory/Cyan) On Ground.
Quick Links:
| Removal of Heater/Brake-Temperature Monitoring Unit (HMBU) | AMM 30-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Heater/Brake-Temperature Monitoring Unit (HMBU) | AMM 30-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Pitot-Static Probes | AMM 34-11-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Pitot-Static Probes | AMM 34-11-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between HBMU2 and standby pitot static probe heater.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Measure the resistance of pitot standby static probe heater.
STBY PITOT-STATIC head heater should be 20 ohms ±10 ohms at ambient temperature.
STBY PITOT-STATIC probe base heater should be 210 ohms approximately.- If resistance within range, go to step 4.
- If resistance out of range, continue with next step.
- Replace standby pitot static probe.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap HBMUs.
- Do close out.