08/06/24
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | EMER 9-2 |
| System Description: | 30-12-00 |
| Schematic Diagram: | 30-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The temperature of the wing anti-icing system is too high.
Possible Causes:
- Anti-icing Temperature Sensor is not correctly installed
- Outboard Anti-Icing Temperature Sensor is not correctly installed
- Inboard Anti-Icing Temperature Sensor
- Outboard Anti-Icing Temperature Sensor
- Anti-Icing Modulating-and-Shutoff Valve
- There is a fracture in the Left Slat 4 Piccolo Duct
- There is a fracture in the Right Slat 4 Piccolo Duct
- Data Acquisition Units (DAU)
- Bleed Management Controller (BMC)
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-36-0365 - Bleed management controller – Data Gathering to reduce No Fault Found (NFF) rate
- SB 700-31-020 - FLIGHT DATA RECORDING (FDR) SYSTEM – INSTALLATION OF THE FORCE TRANSDUCER UNITS (FTU) AND ACTIVATION OF THE CREW FORCE MEASURING SYSTEM (CFMS) 2002
Forum Articles/Infoservice/Newsletter: None
NOTES:
- Questionnaire for replacing the BMC. Follow instructions using this (Fill out form)
- BMC NFF Action:
- To support the technical investigation, FSRs and Service Centers are requested to perform an NVM download and complete a condition report and (BMC) PN GG546-1017-XX questionnaire when troubleshooting or removing a Bleed Management Controller (BMC) PN GG546-1017-XX.
- To avoid the display of any Bleed related CAS nuisance message after replacement of BMC due to internal failure, follow AW700-36-0365 instructions.
- Proceed to a QAR (if available) download of the last three flights (Aircraft meeting FAR part 135.172).
-BMC NVM download
-IAC CAS messages download
Quick Links:
| Removal of Bleed Management Controller (BMC) | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Bleed Management Controller (BMC) | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Anti-Icing Temperature Sensors | AMM 30-11-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Anti-Icing Temperature Sensors | AMM 30-11-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access the Active Faults/Stored Faults as per AMM Tasks.
- Select related CAIMS message below: