Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

10/29/19

Message Overview:

SG 2 FAIL
(Caution)

DDG Reference: None
Pilot Action (QRH): ABNORM 12-10
System Description: 31-40-00
Schematic Diagram: 31-41-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 31-41-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The IAC symbol generator transmits incorrect or no data to the EFDUs (through the reversion control panel).

NOTE: For this condition, one or more of the EFDUs do not have a display.

Possible Causes:

  • Interface to Integrated Avionics Computers (IAC) Symbol Generator
  • Integrated Avionics Computers (IAC) Symbol Generator

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Integrated Avionics Computers (IAC) AMM 31-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Integrated Avionics Computers (IAC) AMM 31-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Integrated Maintenance Test (IMT) Fault Code Look-up AMM 45-45-00-970-826 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Select related CAIMS message below: