07/26/19
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ADVISORY 11-4 |
| System Description: | 31-44-00 |
| Schematic Diagram: | 31-44-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-44-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Bus controller 1 in the IAC system cannot control the ASCB data.
Possible Causes:
- Bus Controller 1
- Bus Controller 1 Interface
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
For in depth ASCB BUS troubleshooting recommendations and test equipment detail, refer to the ASCB Fault Isolation Guide.
Quick Links:
| Operational Test of the Digital Bus System | AMM 31-44-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Integrated Maintenance Test (IMT) Fault Code Look-up | AMM 45-45-00-970-826 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Select related CAIMS message below: