08/10/21
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ADVISORY 11-4 |
| System Description: | 31-44-00 |
| Schematic Diagram: | 31-44-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-44-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The member system data that is usually transmitted on the primary and secondary ASCB is incorrect, is available on only one bus or is not available at all. The message is available only during a WOW condition.
Possible Causes:
- Primary and/or Secondary Bus in ASCB
- ASCB Isolation Couplers and/or Resistor
- Bus Controller in the IAC System
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
For in depth ASCB BUS troubleshooting recommendations and test equipment detail, refer to the ASCB Fault Isolation Guide.
Quick Links:
| Removal of the Isolation Couplers | AMM 31-44-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Isolation Couplers | AMM 31-44-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Digital Bus System | AMM 31-44-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Integrated Maintenance Test (IMT) Fault Code Look-up | AMM 45-45-00-970-826 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Select related CAIMS message below: