WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/29/19

Message Overview:

IAC 1 AURAL FAIL
(Advisory)

DDG Reference: No Go
Pilot Action (QRH): ADVISORY 11-8
System Description: 31-50-00
Schematic Diagram: 31-41-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 31-52-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

IAC 1 cannot supply its usual aural warnings and display functions.

Possible Causes:

  • Integrated Avionics Computer (IAC) 1
  • Aural Warning Components

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to System Diagnostics AMM 45-45-00-970-804 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Integrated Avionics Computers (IAC) AMM 31-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Integrated Avionics Computers (IAC) AMM 31-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Integrated Maintenance Test (IMT) Fault Code Look-up AMM 45-45-00-970-826 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. On the CAIMS PMAT, get access to system diagnostics (AMM TASK 45-45-00-970-804) and do the FWC Discrete Input Test, IAC EDS/Core Test, and X-side Aural Warnings Test.
  2. After each test is completed, look for the TEST RESULTS page and record the fault type and code(s) for each IMT fault.
  3. Do the IMT fault code look-up procedure (AMM TASK 45-45-00-970-826) to find the applicable troubleshooting procedures.
  4. Carry out troubleshooting procedures.
  5. Do close out.