07/29/19
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ABNORM 13-7 |
| System Description: | 32-61-00 |
| Schematic Diagram: | 32-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 32-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
WOW failure is detected.
Possible Causes:
- Nose Gear WOFW Proximity Sensors
- Main Gear WOW Proximity Sensor(s)
- Landing-Gear Electronic Control-Unit (LG ECU)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Landing-Gear Electronic Control-Unit (LG ECU) | AMM 32-31-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Landing-Gear Electronic Control-Unit (LG ECU) | AMM 32-31-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Nose Gear WOFW Proximity Sensors | AMM 32-61-05-000-807 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Nose Gear WOFW Proximity Sensors | AMM 32-61-05-400-807 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Main Gear WOW Proximity Sensors | AMM 32-61-01-000-806 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Main Gear WOW Proximity Sensors | AMM 32-61-01-400-806 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access the Active Faults/Stored Faults as per AMM Tasks.
- Select related CAIMS message below: