Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/16/21

Message Overview:

ADC 1 MISCMP
(Caution)

DDG Reference: None
Pilot Action (QRH): AVNC 02-2
System Description: 34-11-00
Schematic Diagram: 34-11-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 34-11-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

The data from MADC 1 system does not agree with the other two MADCs (this is an external fault or probe fault).

Possible Causes:

  • Air Data System is not calibrated correctly
  • Pitot-Static System has a leak
  • Temperature Probe
  • Pitot-Static Probe
  • Probe Heaters

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter:

Notice To Operators (NTO): None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Functional Test of the Air Data Computer System AMM 34-11-00-720-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Functional Test of the Pitot-Static Systems AMM 34-11-00-720-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Leak Test of the Pitot-Static System 1 AMM 34-11-00-790-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Leak Test of the Pitot-Static System 2 AMM 34-11-00-790-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Leak Test of the Pitot-Static System 3 AMM 34-11-00-790-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Detailed Inspection of the Pitot-Static Probes AMM 34-11-01-220-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Pitot Line P1 Contamination Removal AMM 34-11-01-100-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Static Line P1 S1/P STBY S2 Contamination Removal AMM 34-11-01-100-805 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Static Line P2 S1/P3 S2 Contamination Removal AMM 34-11-01-100-806 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Static Line P3 S1/P2 S2 Contamination Removal AMM 34-11-01-100-807 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Static Line P STBY S1/P1 S2 Contamination Removal AMM 34-11-01-100-808 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to System Diagnostics AMM 45-45-00-970-804 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Integrated Maintenance Test (IMT) Fault Code Look-up AMM 45-45-00-970-826 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Using the PMAT, access CAIMS, System Diagnostics, ATA 34, Air Data Computer and perform a test of the associated ADC. If the test fails, an IMT failure code will be displayed. Record the code (AMM 45-45-00-970-804 - Access to System Diagnostics).
  2. In the PMAT Start Menu, select AIRCRAFT DIAGNOSTIC and click on IMT FAILURE CODE LOOKUP to launch the tool (AMM 45-45-00-970-826 - Integrated Maintenance Test (IMT) Fault Code Look-up).
    caims_adc_imt
  3. Select the recorded code from the dropdown menu and perform the troubleshooting steps displayed on the page.

    1. If the fault is isolated and resolved, do close out.
    2. If no code was present or the fault persists, continue with next step.

  4. Do the procedures that follow until the fault of the ADC system is isolated:

    1. Functional test of the ADC system.
    2. Detailed inspection of the pitot-static probes.
    3. All Pitot system 1 contamination removal tasks (see Quick Links: section above)
      NOTE: This step should be performed, regardless if contamination is found in the moisture traps.
    4. Functional test of the pitot-static systems.
    5. Leak test of the pitot-static system 1.
    6. Leak test of the pitot-static system 2.
    7. Leak test of the pitot-static system 3.

  5. Do close out.