02/14/25
Message Overview:
| DDG Reference: | 34-11 |
| Pilot Action (QRH): | ADVISORY 11-2 |
| System Description: | 34-11-00 - Air Data Computer System |
| Schematic Diagram: | 34-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-11-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Set when ADC 2 is unreliable. Degraded static error correction.
Possible Causes:
- Air Data Computer (ADC 2)
- ADC 2 Interface Systems
- DCPC Contactor K2
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-34-0346 - Micro Air Data Computer - Altitude Split Troubleshooting Procedures and No Fault Found Update
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
NOTES:
- Use the No. 2 Micro Air Data Computer (MADC) or Advanced Micro Air Data Computer (AMADC) Troubleshooting Checklist and the Flight Test Data Sheet (Appendix A in the AW700-34-0346).
Quick Links:
| Connect Electrical Power to the Aircraft | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-861-801 |
| Remove the Electrical Power from the Aircraft | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-861-802 |
| Removal of the DC Power Center (DCPC) L-Series Contactor | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-61-53-000-801 |
| Installation of the DC Power Center (DCPC) L-Series Contactor | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-61-53-400-801 |
| Operational Test of the DC Power Center (DCPC) L-Series Contactor | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-61-53-710-801 |
| Removal of the Micro Air-Data Computers | [ G5000 ] [ Global Express ] [ Global XRS ] AMM34-11-09-000-801 |
| Installation of the Micro Air-Data Computers | [ G5000 ] [ Global Express ] [ Global XRS ] AMM34-11-09-400-801 |
| Operational Test of the Micro Air-Data Computers | [ G5000 ] [ Global Express ] [ Global XRS ] AMM34-11-09-710-801 |
| Access to Active Faults | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-802 |
| Access to Stored Faults | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-803 |
| Standard Aircraft Configuration for Maintenance | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-801 |
| Aircraft Walkaround (for Maintenance) | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-802 |
Troubleshooting Recommendations:
- Check if the following CAS messages are posted:
- FMS#2 FAIL (cyan)
- ADC 2 DEGRADED (cyan)
- ADC 3 FAIL (cyan)
- If YES, continue with next step.
- If NO go to step 3.
- Pull ESS BUS TRU 1 CB, (To drive DCPC reconfiguration) Are the CAS messages posted?
- If YES, continue with next step.
- If NO, DCPC contactor K2 is highly suspected, inspect the contactor.
- Using PMAT, access the Active Fault/Stored Fault as per AMM Tasks.
- Select related CAIMS message below: