07/31/19
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ADVISORY 11-5 |
| System Description: | 34-60-00 |
| Schematic Diagram: | 34-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Either FMS 3 is reporting a failure or the FMS 3 data transmitted is invalid.
Possible Causes:
- Flight Management Computer (FMC) 3
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-31-0563 - Batch 3.3 Software upgrade - In-Service observations (FMS 1 FAIL)
Forum Articles/Infoservice/Newsletter: None
Quick links:
| Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Stored Faults | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Flight Management System Control-and-Display Units (FMS CDU) | AMM 34-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight Management System Control-and-Display Units (FMS CDU) | AMM 34-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access the Active Faults/Stored Faults as per AMM Tasks.
- Select related CAIMS message below: