05/03/21
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ADVISORY 13-2 |
| System Description: | 35-20-00 |
| Schematic Diagram: | 35-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 35-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
- Oxygen is supplied to Passenger Masks manually
- When Cabin Altitude reaches 14,500 +500 / -700 ft
- Oxygen Test Switch in test
If any above condition is not true, then the following steps apply.
Possible Causes:
- Oxygen Test Switch
- Oxygen Line Pressure Switch
- Data Acquisition Unit (DAU) 4
- Relay K750 (in Copilot Bulkhead)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Removal of Data Acquisition Units | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Data Acquisition Units | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Passenger Oxygen Control Panel | AMM 35-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Passenger Oxygen Control | AMM 35-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Interchange DAUs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring check between DAU 4, K750, Oxygen line pressure switch and Oxygen test switch.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Oxygen line pressure switch.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Passenger Oxygen Control.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace K750.
- Do close out.