08/19/22
Message Overview:
| DDG Reference: | 49-52-01 |
| Pilot Action (QRH): | ABNORM 4-2 |
| System Description: | 36-11-00 |
| Schematic Diagram: | 36-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 36-11-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The position of the butterfly plate of the load control valve does not agree with the signal that was sent by the FADEC.
Possible Causes:
- Load Control Valve (LCV)
- Left Bleed Leak Detection Loops
- Right Bleed Leak Detection Loops
- Cross Bleed Valve (CBV)
- Bleed Management Controller (BMC)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-36-0365 - Bleed management controller - Data Gathering to reduce No Fault Found (NFF) rate
Forum Articles/Infoservice/Newsletter:
BMC NFF Action:
To support the technical investigation, FSRs and Service Centers are requested to perform an NVM download and complete a condition report and (BMC) PN GG546-1017-XX questionnaire when troubleshooting or removing a Bleed Management Controller (BMC) PN GG546-1017-XX.
NOTE: To avoid the display of any Bleed related CAS nuisance message after replacement of BMC due to internal failure, follow AW700-36-0365 instructions.
- Proceed to a QAR (if available) download of the last three flights (Aircraft meeting FAR part 135.172.), SB 700-31-020
- BMC NVM download
- IAC CAS messages download
Quick Links:
| Bleed Air Leak Detection System - Maintenance Practices | AMM 36-12-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Bleed Management Controller (BMC) | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Bleed Management Controller (BMC) | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Cross Bleed Valve | AMM 36-11-29-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Cross Bleed Valve | AMM 36-11-29-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Load Control Valve | AMM 49-52-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Load Control Valve | AMM 49-52-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Select related CAIMS message below.