Message Overview:
| DDG Reference: | 30-11-02 30-11-04 |
| Pilot Action (QRH): | ABNORM 4-2 |
| System Description: | 36-12-00 |
| Schematic Diagram: | 36-12-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 36-12-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
There is a failure in the left bleed system.
Possible Causes:
- An overpressure condition is sensed by the Left Bleed Pressure Transducer
- Bleed Management Controller (BMC) 1
- Bleed Management Controller (BMC) 2
- Air-Conditioning System Controller (ACSC) 1
- Data Acquisition Units (DAU) 1
- Data Acquisition Units (DAU) 2
- Left Pressure-Regulating-Valve (PRV)
- Left High-Pressure-Valve (HPV)
- Left Bleed Pressure Transducer (BPT)
- Left Intermediate Pressure Transducer (IPT)
- Left Bleed Leak-Detection-Loops
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-36-0365 - BMC NFF Action
Forum Articles/Infoservice/Newsletter:
BMC NFF Action:
To support the technical investigation, FSRs and Service Centers are requested to perform an NVM download and complete a condition report and (BMC) PN GG546-1017-XX questionnaire when troubleshooting or removing a Bleed Management Controller (BMC) PN GG546-1017-XX.
NOTE: To avoid the display of any Bleed related CAS nuisance message after replacement of BMC due to internal failure, follow AW700-36-0365 instructions.
- Proceed to a QAR (if available) download of the last three flights (Aircraft meeting FAR part 135.172), SB 700-31-020
- BMC NVM download
- IAC CAS messages download
Quick Links:
| Bleed Air Leak Detection System - Maintenance Practices | AMM 36-12-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Leak Test of the Bleed Air System | AMM 36-11-00-790-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Bleed Management Controller (BMC) | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Bleed Management Controller (BMC) | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access the Active Faults/Stored Faults as per AMM Tasks.
- Select related CAIMS message below: