Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

08/16/19

Message Overview:

APU FUEL SOV CLSD
(Status)

DDG Reference: 28-21-04
Pilot Action (QRH): STATUS-1
System Description: 28-21-00
Schematic Diagram: 28-21-00  [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-21-00  [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

APU FUEL SOV CLSD (Status) shows when the conditions that follow occur:

  • APU fire handle is pulled.
  • APU feed shut-off valve is closed.
  • APU SOVS CLSD (Status), is not shown.

This troubleshooting applies when it is not under normal conditions.

Possible Causes:

  • Auxiliary Power Unit (APU) Fire Handle Switch (A211)
  • Ground Stud (GS526)
  • Fuel Computer (FMQGC) (A47)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Fuel Computer (FMQGC) AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Fuel Computer (FMQGC) AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the APU Fire Extinguishing Control Panel (A211) AMM 26-21-13-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the APU Fire Extinguishing Control Panel (A211) AMM 26-21-13-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Remove the FMQGC and inspect the tray, connectors and pins. Make sure connector A47AP1 - G10 is not damaged, bent and is secured properly into place.

    1. If the check is good, continue with the next step.
    2. If the check is not good, rectify/replace as necessary.

  2. Pull the APU fire handle and do the wiring continuity check below:

    FROM TO EXPECTED RESULT RESULT
    A47AP1 - G10 Airframe Ground Continuity

    1. If the wiring check is good, go to step 5.
    2. If the wiring check is not good, continue with the next step.

  3. Remove the Fire Handle Panel (AP12) and disconnect A211P1. Perform wiring continuity check per table below:

    FROM TO EXPECTED RESULT RESULT
    A211P1 - 15 A211P1 - 4 Continuity
    A211P1 - 15 Airframe Ground Continuity

    1. If the wiring from A211P1 - 15 to A211P1 - 4 is not good then suspect the APU fire handle switch (A211).
    2. If the wiring from A211P1 - 15 to airframe ground is not good then repair or replace wiring from APU Fire Handle Switch to GS526, or GS526.
    3. If the wiring check is good, continue with the next step.

  4. Perform wiring continuity check per table below:

    FROM TO EXPECTED RESULT RESULT
    A211P1 - 4 A47AP1 - G10 Continuity

    1. If the wiring check is good continue with next step.
    2. If the wiring check is not good then repair or replace wiring from the APU Fire Handle Switch to the FMQGC.

  5. Re-install or re-rack the FMQGC making sure it is fully and properly pushed into place. Is the fault still present?

    1. If YES, then suspect the FMQGC.
    2. If NO, then go to next step.

  6. Do close out.