Message Overview:
| DDG Reference: | 28-21-04 |
| Pilot Action (QRH): | STATUS-1 |
| System Description: | 28-21-00 |
| Schematic Diagram: | 28-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
APU FUEL SOV CLSD (Status) shows when the conditions that follow occur:
- APU fire handle is pulled.
- APU feed shut-off valve is closed.
- APU SOVS CLSD (Status), is not shown.
This troubleshooting applies when it is not under normal conditions.
Possible Causes:
- Auxiliary Power Unit (APU) Fire Handle Switch (A211)
- Ground Stud (GS526)
- Fuel Computer (FMQGC) (A47)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Fuel Computer (FMQGC) | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fuel Computer (FMQGC) | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the APU Fire Extinguishing Control Panel (A211) | AMM 26-21-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Fire Extinguishing Control Panel (A211) | AMM 26-21-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the FMQGC and inspect the tray, connectors and pins. Make sure connector A47AP1 - G10 is not damaged, bent and is secured properly into place.
- If the check is good, continue with the next step.
- If the check is not good, rectify/replace as necessary.
- Pull the APU fire handle and do the wiring continuity check below:
FROM TO EXPECTED RESULT RESULT A47AP1 - G10 Airframe Ground Continuity - If the wiring check is good, go to step 5.
- If the wiring check is not good, continue with the next step.
- Remove the Fire Handle Panel (AP12) and disconnect A211P1. Perform wiring continuity check per table below:
FROM TO EXPECTED RESULT RESULT A211P1 - 15 A211P1 - 4 Continuity A211P1 - 15 Airframe Ground Continuity - If the wiring from A211P1 - 15 to A211P1 - 4 is not good then suspect the APU fire handle switch (A211).
- If the wiring from A211P1 - 15 to airframe ground is not good then repair or replace wiring from APU Fire Handle Switch to GS526, or GS526.
- If the wiring check is good, continue with the next step.
- Perform wiring continuity check per table below:
FROM TO EXPECTED RESULT RESULT A211P1 - 4 A47AP1 - G10 Continuity - If the wiring check is good continue with next step.
- If the wiring check is not good then repair or replace wiring from the APU Fire Handle Switch to the FMQGC.
- Re-install or re-rack the FMQGC making sure it is fully and properly pushed into place. Is the fault still present?
- If YES, then suspect the FMQGC.
- If NO, then go to next step.
- Do close out.