Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/03/19

Message Overview:

Fault Message:

[CPC1] OUTFLOW VLV #2 DSBL CMD /WRG

Fault Code:

2137322ABG

Associated CAS:

None

Reporting LRU: Cabin Pressure Controller (CPC) 1
System Description: 21-31-00
Schematic Diagram: 21-31-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-31-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

A disagree has been detected between the "DISABLE CMD" discrete output sent by Cabin Pressure Controller (CPC) 1 to Outflow Valve (OFV) 2 and the feed back received from OFV 2 (ARINC 422).

Possible Causes:

  • Cabin Pressure Controller (CPC) 1 (A21)
  • AFT Outflow Valve (OFV) 2 (L9)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Outflow Valves AMM 21-31-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Outflow Valves AMM 21-31-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform wiring checks of the DISABLE CMD wire between CPC 1 and OFV 2.

    1. If wiring checks are not good, repair the defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  2. Replace OFV 2.
  3. Do close out.