Message Overview:
Message Name:
[CPC1] CPCS CONTROL PANEL /WRG
Message Code:
2137429ABG
Associated CAS:
| Reporting LRU: | Cabin Pressure Controller (CPC) 1 |
| System Description: | 21-31-00 |
| Schematic Diagram: | 21-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-31-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The Cabin Pressure Controller (CPC) 1 detects a problem with the PRESSURIZATION Control Panel.
Possible Causes:
- Pressurization Control Panel (AP9)
- Cabin Pressure Controller (CPC) 1 (A21)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Cabin Pressure Controllers | AMM 21-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Cabin Pressure Controllers | AMM 21-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the PRESSURIZATION Control Panel | AMM 21-31-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the PRESSURIZATION Control Panel | AMM 21-31-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Interchange CPC 1 with CPC 2.
- If system checks are good, replace CPC 1 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks of the wire between CPC 1 and PRESSURIZATION control panel.
- If the wiring checks are not good, repair the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- On the pressurization control panel, interchange relay K2 with relay K4.
- If system checks are good, replace relay K2 and do close out.
- If fault remains, continue with next step.
- On the pressurization control panel, interchange relay K1 with relay K3.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- On the pressurization control panel do a general wiring inspection and repair any defect. Check for damaged wire or unlock pins at AP9J1, AP9J2, on relay bases (K1, K2, K3, K4) and on switch AP9SDS1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace PRESSURIZATION control panel.
- Do close out.