06/03/19
Message Overview:
Fault Message:
[CPC2] OUTFLOW VLV #2 DSBL CMD /WRG
Fault Code:
2138322ABG
Associated CAS:
| Reporting LRU: | Cabin Pressure Controller (CPC) 2 |
| System Description: | 21-31-00 |
| Schematic Diagram: | 21-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-31-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
A disagree has been detected between the "DISABLE CMD" discrete output sent by Cabin Pressure Controller (CPC) 2 to Outflow Valve (OFV) 2 and the feed back received from OFV 2 (ARINC 422).
Possible Causes:
- AFT Outflow Valve (OFV) 2 (L9)
- Cabin Pressure Controller (CPC) 2 (A22)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Outflow Valves | AMM 21-31-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Outflow Valves | AMM 21-31-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks of the "DISABLE CMD" wire between CPC2 and OFV2.
- If wiring checks are good, continue with next step.
- If wiring checks are not good, repair defective associated wiring and do close out.
- Replace OFV 2.
- Do close out.